10 resultados para Capillary Electrochromatography (CEC)

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Molecularly imprinted polymers (MIP's) have been applied in several areas of analytical chemistry, including the modification of electrodes. The main purpose of such modification is improving selectivity; however, a gain in sensitivity was also observed in many cases. The most frequent approaches for these modifications are the electrodeposition of polymer films and sol gel deposits, spin and drop coating and self-assembling of films on metal nanoparticles. The preparation of bulk (body) modified composites as carbon pastes and polymer agglutinated graphite have also been investigated. In all cases several analytes including pharmaceuticals, pesticides, and inorganic species, as well as molecules with biological relevance have been successfully used as templates and analyzed with such devices in electroanalytical procedures. Herein, 65 references are presented concerning the general characteristics and some details related to the preparation of MIP's including a description of electrodes modified with MIP's by different approaches. The results using voltammetric and amperometric detection are described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A thin-layer electrochemical flow cell coupled to capillary electrophoresis with contactless conductivity detection (EC-CE-(CD)-D-4) was applied for the first time to the derivatization and quantification of neutral species using aliphatic alcohols as model compounds. The simultaneous electrooxidation of four alcohols (ethanol, 1-propanol, 1-butanol, and 1-pentanol) to the corresponding carboxylates was carried out on a platinum working electrode in acid medium. The derivatization step required 1 min at 1.6 V vs. Ag/AgCl under stopped flow conditions, which was preceded by a 10 s activation at 0 V. The solution close to the electrode surface was then hydrodynamically injected into the capillary, and a 2.5 min electrophoretic separation was carried out. The fully automated flow system operated at a frequency of 12 analyses per hour. Simultaneous determination of the four alcohols presented detection limits of about 5 x 10(-5) mol As a practical application with a complex matrix, ethanol concentrations were determined in diluted pale lager beer and in nonalcoholic beer. No statistically significant difference was observed between the EC-CE-(CD)-D-4 and gas chromatography with flame ionization detection (GC-FID) results for these samples. The derivatization efficiency remained constant over several hours of continuous operation with lager beer samples (n = 40).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Terbinafine hydrochloride (TerbHCl) is an allylamine derivative with fungicidal action, especially against dermatophytes. Different analytical methods have been reported for quantifying TerbHCl in different samples. These procedures require time-consuming sample preparation or expensive instrumentation. In this paper, electrochemical methods involving capillary electrophoresis with contactless conductivity detection, and amperometry associated with batch injection analysis, are described for the determination of TerbHCl in pharmaceutical products. In the capillary electrophoresis experiments, terbinafine was protonated and analyzed in the cationic form in less than 1 min. A linear range from 1.46 to 36.4 mu g mL(-1) in acetate buffer solution and a detection limit of 0.11 mu g mL(-1) were achieved. In the amperometric studies, terbinafine was oxidized at +0.85 V with high throughput (225 injection h(-1)) and good linear range (10-100 mu mol L-1). It was also possible to determine the antifungal agent using simultaneous conductometric and potentiometric titrations in the presence of 5% ethanol. The electrochemical methods were applied to the quantification of TerbHCl in different tablet samples; the results were comparable with values indicated by the manufacturer and those found using titrimetry according to the Pharmacopoeia. The electrochemical methods are simple, rapid and an appropriate alternative for quantifying this drug in real samples. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A capillary electrophoretic enantioselective method with UV detection was developed and validated for the simultaneous quantification of zopiclone enantiomers and its impurities, zopiclone-N-oxide enantiomers, and 2-amino-5-chloropyridine, in tablets. The analytes were extracted from the tablets using ACN and were separated in an uncoated fused-silica capillary (50 mu m, 42 cm effective length, 50 cm total length) using 80 mM sodium phosphate buffer pH 2.5 and 5 mM carboxymethyl-beta-cyclodextrin as running buffer. The analytes and the internal standard (trimethoprim) were detected at 305 and 200 nm, respectively. A voltage of 27 kV was applied and the capillary temperature was maintained at 25 degrees C. All enantiomers were analyzed within 8 min and linear calibration curves over the concentration range of 0.40.8 mg mL-1 for each zopiclone enantiomer, 0.81.6 mu g mL-1 for 2-amino-5-chloropyridine and 0.40.8 mu g mL-1 for each zopiclone-N-oxide enantiomer were obtained. The coefficients of correlation obtained for the linear curves were greater than 0.99. The intra-day and inter-day accuracy and precision were lower than 2% for all analytes. This validated method was employed to study the degradation and racemization of zopiclone under stress conditions. This application demonstrated the importance of a stability-indicating assay method for this drug.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The enzyme purine nucleoside phosphorylase (PNP) is a target for the discovery of new lead compounds employed on the treatment severe T-cell mediated disorders. Within this context, the development of new, direct, and reliable methods for ligands screening is an important task. This paper describes the preparation of fused silica capillaries human PNP (HsPNP) immobilized enzyme reactor (IMER). The activity of the obtained IMER is monitored on line in a multidimensional liquid chromatography system, by the quantification of the product formed throughout the enzymatic reaction. The Km value for the immobilized enzyme was about twofold higher than that measured for the enzyme in solution (255 +/- 29.2 mu M and 133 +/- 114.9 mu M, respectively). A new fourth-generation immucillin derivative (DI4G: IC50 = 40.6 +/- 0.36 nM), previously identified and characterized in HsPNP free enzyme assays, was used to validate the IMER as a screening method for HsPNP ligands. The validated method was also used for mechanistic studies with this inhibitor. This new approach is a valuable tool to PNP ligand screening, since it directly measures the hypoxanthine released by inosine phosphorolysis, thus furnishing more reliable results than those one used in a coupled enzymatic spectrophotometric assay. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aerobic exercise training (ET) has been established as an important non-pharmacological treatment of hypertension, since it decreases blood pressure. Studies show that the skeletal muscle abnormalities in hypertension are directly associated with capillary rarefaction, higher percentage of fast-twitch fibers (type II) with glycolytic metabolism predominance and increased muscular fatigue. However, little is known about these parameters in hypertension induced by ET. We hypothesized that ET corrects capillary rarefaction, potentially contributing to the restoration of the proportion of muscle fiber types and metabolic proprieties. Twelve-week old Spontaneously Hypertensive Rats (SHR, n=14) and Wistar Kyoto rats (WKY, n=14) were randomly assigned into 4 groups: SHR, trained SHR (SHR-T), WKY and trained WKY (WKY-T). As expected, ten weeks of ET was effective in reducing blood pressure in SHR-T group. In addition, we analyzed the main markers of ET. Resting bradycardia, increase of exercise tolerance, peak oxygen uptake and citrate synthase enzyme activity in trained groups (WKY-T and SHR-T) showed that the aerobic condition was achieved. ET also corrected the skeletal muscle capillary rarefaction in SHR-T. In parallel, we observed reduction in percentage of type IIA and IIX fibers and simultaneous augmented percentage of type I fibers induced by ET in hypertension. These data suggest that ET prevented changes in soleus fiber type composition in SHR, since angiogenesis and oxidative enzyme activity increased are important adaptations of ET, acting in the maintenance of muscle oxidative metabolism and fiber profile.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents simple, rapid, precise and accurate stability-indicating HPLC and CE methods, which were developed and validated for the determination of nitrendipine, nimodipine and nisoldipine. These drugs are calcium channel antagonists of the 1,4-dihydropyridine type which are used in the treatment of cardiovascular diseases. Experimental results showed a good linear correlation between the area and the concentration of drugs covering a relatively large domain of concentration in all cases. The linearity of the analytical procedures was in the range of 2.0-120.0 mu g mL-1 for nitrendipine, 1.0-100.0 mu g mL(-1) for nimodipine and 100.0-600.0 mu g mL(-1) for nisoldipine, the regression determination coefficient being higher than 0.99 in all cases. The proposed methods were found to have good precision and accuracy. The chemical stability of these drugs was determined under various conditions and the methods have shown adequate separation for their enantiomers and degradation products. In addition, degradation products produced as a result of stress studies did not interfere with the detection of the drugs' enantiomers and the assays can thus be considered stability-indicating.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background To identify the most appropriate cut-off points of fasting glycemia for the screening of diabetes mellitus type 2 (DM2) with the comparison of the properties of capillary glycemia (CG) and venous blood plasma glycemia (PG) in a population of Japanese origin from the community of Mombuca, Guatapará - SP, Brazil. Methods This was a population-based descriptive cross-sectional study conducted on a sample of 131 individuals of both genders aged 20 years or more (66.8% of the target population). CG was measured with a glucometer in a blood sample obtained from the fingertip and PG was determined by an enzymatic method (hexokinase) in venous blood plasma, after a 10-14 hour fast in both cases. Data were analyzed by the receiver operating characteristic (ROC) curve in order to identify the best cut-off point for fasting glycemia (CG and PG) for the diagnosis of DM, using the 2-hour plasma glycemia > 200 mg/dl as gold - standard. Results The ROC curve revealed that the best cut-off point for the screening of DM was 110 mg/dl for CG and 105 mg/dl for PG, values that would optimize the relation between individuals with positive and false-positive results. The area under the ROC curve was 0.814 for CG (p < 0.01) and 0.836 for PG (p < 0.01). Conclusions The cut-off points of 105 mg/dl(5.8 mmol/l) for PG and of 110 mg/dl(6.1 mmol/l) for CG appear to be the most appropriate for the screening of DM2 in the population under study, with emphasis on the fact that the value recommended for CG is 5 mg/dl higher than that for PG, in contrast to WHO recommendations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Permanecem as controvérsias sobre a utilização de circulação extracorpórea (CEC) na cirurgia de revascularização miocárdica (CRM). O objetivo deste estudo foi avaliar o impacto do 2000 Bernstein Parsonnet (2000BP) e EuroSCORE (EU) para escolha de CEC na CRM. MÉTODOS: Foram submetidos à CRM 1.551 pacientes consecutivos. CEC foi utilizada em 1.121 (72,3%) pacientes. O desempenho do 2000BP e EU para a amostra foi avaliado mediante testes de calibração, discriminação e correlação. Para ambos os escores de risco, o aumento do valor do escore e a presença de CEC tiveram relação direta com maior chance de óbito (P<0,05). Portanto, com essas duas variáveis foi construído um modelo de regressão logística para cada escore de risco, com a finalidade de determinar em que valor do escore a presença de CEC aumenta significativamente a chance de óbito. RESULTADOS: A calibração, ao igual que a área abaixo da curva ROC para o grupo com CEC [2000BP=0,80; EU=0,78] e sem CEC [2000BP=0,81; EU=0,85] foram adequadas. A correlação de Spearman para os grupos com e sem CEC foi de 0,66 (P<0,001) e 0,62 (P<0,001), respectivamente. No 2000BP, para um valor>17,75, a presença de CEC aumentou a chance de óbito para 7,4 [IC95% (4,4-12,3), P<0,0001]. No EU, para um valor>4,5, a presença de CEC aumentou a chance de óbito para 5,4 [IC95% (3,3-9), P<0,0001]. CONCLUSÃO: Na tomada de decisões, o 2000BP>17,75 ou o EU>4,5 orientam a identificar pacientes que quando submetidos a CRM com CEC têm chance de óbito aumentada significativamente.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the metabolic control of diabetes mellitus patients registered in a capillary glucose self-monitoring program at home. METHODS: In this longitudinal retrospective study, 97 subjects at four health institutions in a Brazilian city were followed during 37 months between 2005 and 2008. The health files were analyzed of patients selected to register the evolution of variables related to capillary glucose self-monitoring at home and metabolic control of diabetes mellitus. RESULTS: During the assessment, both mean and monthly percentages of capillary blood glucose measurements at home decreased from 34.1 (65.1%) to 33.6 (64.8%), respectively (p <0.001). Mean HbA1c levels dropped from 9.20% to 7.94% (p<0.001). HDL cholesterol decreased from 51 mg/dl to 47 mg/dl (p=0.001). CONCLUSION: Patients' metabolic control improved, characterized by a significant reduction in HbA1C.